SKU
HR-LARGE-PH

Harvest Right PHARMACEUTICAL Large Freeze Dryer w/ 7.2 cfm Pump

Price $4,095.00
$4,845.00

CUSTOMIZE YOUR PRODUCT

Wishlist

Product Video

Videos
Harvest Right Freeze Dryer Overview

60 Educational Vidoes from Harvest Right
 

 

- 10.25 square feet of tray space—nearly twice the capacity of Harvest Right’s standard Large freeze dryer
- Shelf Unit Has shelves for 8 trays (each tray 9″ W x 20.5″ x 0.75″ H)
- 6 liters of ice capacity
 
Warranty
3 year limited warranty
 
Vacuum Pump Each vacuum pump has been factory tested to guarantee 25 microns (25,400 Microns = 1 Inch of Hg) or better and listed CFM performance.
 
Vacuum Pump Technical Specifications Oil: Harvest Right Oil, Robinair Premium High Vacuum Pump Oil or JB Industries Black Gold Vacuum Pump Oil Only DC Motor Energy Efficient Voltage: Standard, 115v, 60Hz Dimensions: 16.3″ x 6″ x 12.1″ Weight: 32lbs Noise: 52 decibels

Oil Changes
This new Industrial Pump rarely needs to have the oil changed or filtered. The pump has a gas ballast feature that makes it so water does not stay in the oil. Because of this, the oil in the pump will be pristine and clear, even after 30 or more batches. You simply won’t need to change the oil until you have run 25 to 40 batches. Whereas, the oil in the standard vacuum pump needs to be changed and filtered every 4 or 5 batches (when using the new 3/8 inch vacuum hose).

Vacuum Pressure
Under cold and hot conditions the Industrial Pump will pull a deeper vacuum than the Standard Pump. Under cold conditions the difference is .05 Pascal for the Industrial Pump and .08 Pascal for the Standard Pump. Whereas, under warm conditions the difference is much greater: .05 Pascal for the Industrial Pump and 2.05 Pascal for the Standard Pump.

Hence, the Industrial Pump is especially not affected by warm, ambient conditions. When temperatures rise, it will pull a vacuum far better than the Standard Pump. The Industrial Pump is just not affected by outside heat. It pulls the same deep vacuum even when it is in a warm environment.

Noise
The Industrial Pump is substantially quieter than the Standard Pump, 52 decibels versus 64 decibels. The Industrial Pump at 52 decibels is about the same as a refrigerator.

Oil Mist Filter
Both pumps come with an oil mist filter. However, the Industrial Pump’s oil mist filter allows for no oil spray at all and it will last much longer.

Power Use
The Industrial Pump uses less power than the Standard Pump (187 watts versus 218 watts).

Amperage
Under hot conditions at ultimate vacuum pressure the Standard Pump pulls 2.1 amps while the Industrial Pump only pulls 1.7 amps. Hence, the Industrial Pump is more efficient.

Weight
The Industrial Pump is easier to move around as it weighs 5 pounds less than the Standard Pump (32 lbs. versus 37 lbs.)

Life
The Industrial Pump is more durable and will last longer than the Standard Pump.

 

Standard Packages

Standard package

 Part description

 Quantity

Part image

 Harvest Right Pharmaceutical Large Freeze Dryer (Oven Rack and Black Gasket Installed on Unit) 1 pc

Power Cord 1 pc
Freeze Dryer Trays 8 pc
Oil Filter
1 pc
Troubleshooting Guide 1 pc
Vacuum Pump Hose 1 pc

 

Vacuum Pump Box

 

 Part description

 Quantity

Part image

Vacuum Pump with Filter Installed  1 pc 
Vacuum Pump Oil 1 pc
Vacuum Pump Owner's Manual 1 pc
Overview

 

- 10.25 square feet of tray space—nearly twice the capacity of Harvest Right’s standard Large freeze dryer
- Shelf Unit Has shelves for 8 trays (each tray 9″ W x 20.5″ x 0.75″ H)
- 6 liters of ice capacity
 
Warranty
3 year limited warranty
 
Vacuum Pump Each vacuum pump has been factory tested to guarantee 25 microns (25,400 Microns = 1 Inch of Hg) or better and listed CFM performance.
 
Vacuum Pump Technical Specifications Oil: Harvest Right Oil, Robinair Premium High Vacuum Pump Oil or JB Industries Black Gold Vacuum Pump Oil Only DC Motor Energy Efficient Voltage: Standard, 115v, 60Hz Dimensions: 16.3″ x 6″ x 12.1″ Weight: 32lbs Noise: 52 decibels

Oil Changes
This new Industrial Pump rarely needs to have the oil changed or filtered. The pump has a gas ballast feature that makes it so water does not stay in the oil. Because of this, the oil in the pump will be pristine and clear, even after 30 or more batches. You simply won’t need to change the oil until you have run 25 to 40 batches. Whereas, the oil in the standard vacuum pump needs to be changed and filtered every 4 or 5 batches (when using the new 3/8 inch vacuum hose).

Vacuum Pressure
Under cold and hot conditions the Industrial Pump will pull a deeper vacuum than the Standard Pump. Under cold conditions the difference is .05 Pascal for the Industrial Pump and .08 Pascal for the Standard Pump. Whereas, under warm conditions the difference is much greater: .05 Pascal for the Industrial Pump and 2.05 Pascal for the Standard Pump.

Hence, the Industrial Pump is especially not affected by warm, ambient conditions. When temperatures rise, it will pull a vacuum far better than the Standard Pump. The Industrial Pump is just not affected by outside heat. It pulls the same deep vacuum even when it is in a warm environment.

Noise
The Industrial Pump is substantially quieter than the Standard Pump, 52 decibels versus 64 decibels. The Industrial Pump at 52 decibels is about the same as a refrigerator.

Oil Mist Filter
Both pumps come with an oil mist filter. However, the Industrial Pump’s oil mist filter allows for no oil spray at all and it will last much longer.

Power Use
The Industrial Pump uses less power than the Standard Pump (187 watts versus 218 watts).

Amperage
Under hot conditions at ultimate vacuum pressure the Standard Pump pulls 2.1 amps while the Industrial Pump only pulls 1.7 amps. Hence, the Industrial Pump is more efficient.

Weight
The Industrial Pump is easier to move around as it weighs 5 pounds less than the Standard Pump (32 lbs. versus 37 lbs.)

Life
The Industrial Pump is more durable and will last longer than the Standard Pump.

 

Copyright © 2008-2023 Across International. All rights reserved.